POWER   Nominal 110/220v 50/60Hz at 600VA. Earth is essential
INPUT   Stepper, 4 to 70 volt + or - polarity or NMEA 0183 Heading NMEA 0183 heading, and all valid heading NMEA (magnetic, Cetrek data)
OUTPUT   Nominal 115v ref, 90v signal, or 110v ref, 55v signal, or50v ref, 68v signal. For Anschutz 50/60v ref 20/24v signal an Anschutz Adaptor is required and should be specified on ordering. Reference output 2 Amp. (Fit external transformer if more current required)Phase output 0.7 Amps per phase. Limited at 2A. Synchro output is removed if overload detected.
DIMENSIONS   300 x 400 x 150mm
APPROVALS   IEC60945